Power Systems : Overhead Insulators & Underground Cables

By Aman Agrawal|Updated : July 6th, 2021

BYJU'S Exam Prep Brings you 60 Days Study Plan for the preparation of DFCCIL Electricals & Electronics Engineering. This Study Plan will be free and will be very beneficial for the students preparing and targeting the DFCCIL Exam. Save this article as it will get updated on a daily basis as scheduled.  

The electrical power is transmission (or distribution) is carried out either by underground cables or by overhead lines. Underground cables are less used for power transmission because the power being transmitted has to cover long distances to meet load centers which obviously costs very high when compared to overhead lines. Another reason being power which is being transmitted is kept at high voltages for economic considerations, therefore a proper insulation is required to cables so that they could withstand higher pressures. Hence, power transmission over long distances is carried out by using overhead lines.

Also, an overhead line is subjected to uncertain weather conditions and other external interferences, which in turn need to use of proper mechanical factors of safety in order to ensure the continuity of operation in the line.

In general, the mechanical strength of the line is designed such that it must sustain against worst weather conditions.

Main Components of Overhead Lines:

The main components of an overhead line are:

(i) Conductors which carry electric power from the sending end to the receiving end.

(ii) Supports which may be poles or towers and keep the conductors at a suitable level (or height) above the ground.

(iii) Insulators which are attached to supports and insulate the conductors from the ground.

(iv) Cross arms which provide support to the insulators.

(v) Others such as lightning arrestors, anti-climbing wires, etc.

 

Types of Insulators:

Pin Type Insulators:

The figure shown below is pin type insulator. As the name suggests, the pin type insulator is secured to the cross-arm on the pole. There is a groove on the upper end of the insulator for housing the conductor. The conductor passes through this groove and is bound by the annealed wire of the same material as the conductor.

byjusexamprep

Suspension Type Insulators

The cost of pin type insulator increases rapidly as the working voltage is increased. Therefore, this type of insulator is not economical beyond 33 kV. For high voltages (>33 kV), suspension type insulators are used as shown in figure below. Suspension type insulator is consisting of number of porcelain discs connected in series by metal links in the form of a string. The conductor is suspended at the bottom end of this string while the other end of the string is secured to the cross-arm of the tower.

byjusexamprep

 

Strain Insulators

When there is a dead end of the line or there is sharp curve, the line is subjected to greater tension. Therefore, strain insulators are used. The assembly for strain type insulator is shown in figure below.

byjusexamprep

Shackle Insulators

Shackle type insulators used for low voltage distribution lines and can be used either in a horizontal position or in a vertical position. Figure shown below shows a shackle insulator fixed to the pole. The conductor in the groove is fixed with a soft binding wire.

byjusexamprep

 

Potential Distribution Over Suspension Insulator String

A string of suspension insulators consists of a number of porcelain discs connected in series through metallic links.

The porcelain portion of each disc is in between two metal links. Therefore, each disc forms a capacitor ‘C’ as shown in figure below, which is known as mutual capacitance or self-capacitance.

If there is only mutual capacitance, then charging current will be same through all the discs and therefore voltage across each unit would have been the same i.e., V/3.

But in practice, capacitance also exists between metal fitting of each disc and tower, known as shunt capacitance C1. Due to shunt capacitance, charging current is not the same through all the discs of the string. Therefore, voltage across each disc will be different, i.e., disc nearest to the line conductor will have the maximum voltage. Thus, V3 will be much more than V2 or V1 as shown in figure below.

byjusexamprep

byjusexamprep

where    n = number of discs in the string.

Methods of Improving String Efficiency:

The various methods for improving string efficiency are as follows:

  1. By using longer cross-arms
  2. By grading the insulators
  3. By using a guard ring

 

UNDERGROUND CABLES

An underground cable essentially consists of one or more conductors covered with suitable insulation and surrounded by a protecting cover. The type of cable to be used depends on the working voltage and service requirements.

In general, a cable must fulfil below mentioned necessary requirements:

  1. The conductor used in cables should be stranded type either made of copper or aluminum with high conductivity, the use of stranded conductor is done to reduce the skin effect.
  2. The conductor size should be such that the cable carries the desired load current without overheating and causes voltage drop within permissible limits.
  3. The cable must have proper thickness of insulation in order to give high degree of safety and reliability at the voltage for which it is used.
  4. The cable must be provided with suitable mechanical protection so that it may withstand on rough use.

The materials used in the manufacture of cables should be such that there is complete chemical and physical stability throughout.

byjusexamprep

The various parts of the cable are as follows:

  1. Cores or Conductors:

A cable may have one or more than one core (conductor) depending upon the type of application it is used for. The conductors are made of tinned copper or aluminium and are usually stranded in order to provide flexibility to the cable.

  1. Insulation:

Each core or conductor is provided with a suitable thickness of insulation, the thickness of layer depends upon the voltage which cable need to withstand. The commonly used materials for insulation are impregnated paper, varnished cambric, or rubber mineral compound.

  1. Metallic sheath:

In order to protect the cable from moisture, gases, or any other damaging liquids (such as acids or alkalis) in the soil and atmosphere, a metallic sheath of lead or aluminium is provided over the insulation.

  1. Bedding:

Over the metallic sheath, a layer of bedding is applied which consists of a fibrous material like jute or hessian tape. The purpose of bedding is to protect the metallic sheath against corrosion and from mechanical injury due to armouring.

  1. Armouring:

Over the bedding, armouring is provided which consists of one or two layers of galvanised steel wire or steel tape. Its purpose is to protect the cable from mechanical injury while laying it and during the course of handling.

  1. Serving:

In order to protect armouring from atmospheric conditions, a layer of fibrous material (like jute) similar to bedding is provided over the armouring, this is known as serving.

Classification of Cables:

Cables for underground service may be classified in two ways i.e., according to

(i) the type of insulating material used

(ii) the voltage

Now, according to voltage cables can be divided into the following groups:

(i) Low-tension (L.T.) cables — up to 1000 V

(ii) High-tension (H.T.) cables — up to 11 kV

(iii) Super-tension (S.T.) cables — from 22 kV to 33 kV

(iv) Extra high-tension (E.H.T.) cables — from 33 kV to 66 kV

(v) Extra Online Classroom Program voltage cables — beyond 132 kV

You can avail of Online Classroom Program for all AE & JE Exams:

Online Classroom Program for AE & JE Exams (12+ Structured LIVE Courses and 160+ Mock Tests)

You can avail of BYJU'S Exam Prep Test Series specially designed for all AE & JE Exams:

BYJU'S Exam Prep Test Series AE & JE (160+ Mock Tests) 

Thanks, 

Team BYJU'S Exam Prep

Sahi Prep Hai to Life Set Hai !!!

Download BYJU'S Exam Prep APP , for best Exam Preparation , Free Mock Test, Live Classes

 

Comments

write a comment

AE & JE Exams

AE & JEAAINBCCUP PoliceRRB JESSC JEAPPSCMPPSCBPSC AEUKPSC JECGPSCUPPSCRVUNLUPSSSCSDEPSPCLPPSCGPSCTNPSCDFCCILUPRVUNLPSPCLRSMSSB JEOthersPracticeMock TestCourse

Follow us for latest updates