Time Left - 15:00 mins
GATE CE 2022: DESIGN OF STEEL STRUCTURES: QUIZ 72
Attempt now to get your rank among 157 students!
Question 1
The condition to be satisfied by Bolt Subjected to Combined Shear and Tension is
Where, = factored shear force acting on the bolt
= design shear capacity
= factored tensile force acting on the bolt
= design tension capacity
Question 2
A simply supported beam with plastic moment capacity 60 kN/m is shown in figure. The collapse load will be _________ kN (round off to nearest integer).
Question 3
Which one of the statement is FALSE?
Question 4
Local buckling failure of the beam can be checked by
1)
2) Increasing the thickness of the web
3) Providing longitudinal stiffeners
4) Providing secondary beams
1)
2) Increasing the thickness of the web
3) Providing longitudinal stiffeners
4) Providing secondary beams
Question 5
Consider the following statements with reference to ‘lug angle’ and select the correct option:
P: Length of end connection of angle or channel section to a gusset plate is reduced by using lug angle
Q: In no case, less than two rivets or two bolts shall be used for attaching the lug angle to gusset plate.
R: In case of channel member, the lug angle and their attachment to gusset plate shall be capable of developing strength of not less than 20% in excess of the force in the outstanding flange of a channel
S: In case of angle member, the lug angle and their connection to gusset plate shall be capable of developing strength of not less than 40% in excess of the force in the outstanding flange of a channel.
The correct statements are
P: Length of end connection of angle or channel section to a gusset plate is reduced by using lug angle
Q: In no case, less than two rivets or two bolts shall be used for attaching the lug angle to gusset plate.
R: In case of channel member, the lug angle and their attachment to gusset plate shall be capable of developing strength of not less than 20% in excess of the force in the outstanding flange of a channel
S: In case of angle member, the lug angle and their connection to gusset plate shall be capable of developing strength of not less than 40% in excess of the force in the outstanding flange of a channel.
The correct statements are
Question 6
A fillet welded joint of 6 mm size is shown in the figure. if the welding is done at site itself, then the safe load (in kN) that can be transmitted by the joint is
[Use LSM]
[Use LSM]
- 157 attempts
- 2 upvotes
- 0 comments
Jun 6ESE & GATE CE